12 comments on “Talk with me”

  1. Thank you for this tip Trevor. We think this is a wonderful website. Just never expected it is to be your own 🙂
    Love to Sue
    Crew of Dizzy Lizzy

    • You should be able to do the Kennet and Avon which is Length 21.95m 72ft Width 4m 13ft 1″ Draft 1.1m 3ft 7″ 2.4m 7ft 10″
      This will take you onto the Thames of which you can sale most of its length.

  2. My friend in France has a converted barge of 145′ x 25′! It has a flat transom with a beam of 25′; will it fit in Naburn Lock? If not, what is the maximum length with a full transom of 25′, please?
    Thank you.

    • I am afraid it will NOT fit by length or width
      Naburn Locks to York Length 42.62m 140ft Beam 7.31m 24ft
      Most wide beam locks are 14ft wide like the Grand Union

      This is a very large vessel which will need road haulage and placing into a marina. It certainly would not be fit to travel on the UK waterways, Even the river Trent it is going to be the maximum of 51.3m 168ft 4″ long 6.09m 20ft 1.83m wide and a draft of 6ft 3.81m 12ft 6″

      • On your “Canal and Lock Sizes” web page you have the Naburn lock as a different size and length – which one is correct ?

        • the sizes that are correct are those displayed on the list. Length 150 foot, beam 25 foot 6 inches. Linton Lock: Length 60 foot, beam 15 foot 4 inches.
          The Linton Lock is another Lock on this waterway which has different sizes which will restrict the passage of boats passing through Naburn lock first.

  3. Hello Trevor

    We have an issue with our Inverter and would appreciate any advice you have to offer.

    At present the inverter shows “overload” and we have no direct mains power to the boat.

    When fault finding, we checked our 6 leisure batteries and one was looking a bit weak so we bypassed it just in case it was causing an issue with the inverter. We also disconnected the inverter secondary display panel inside the cabin as we had heard these can also cause issues with the inverters. This seemed to resolved matters for a short time, however, the fault reappeared.

    Coincidentally at the same time with the inverter issue we realised we had a problem with the central heating. We have Kabola central heating and believe the issue to be the pump which we have now replaced, but until we can get the inverter to work we wont know if we have resolved the issue with the heating.

    We are going to try and bypass the inverter and run the mains straight to the heating. Do you think it is a good idea or will it cause further issues down the track?

    As we are new to boating and learning as we go, we would appreciate your wisdom and any help to resolve our problem.

    Kind regards, John and Michelle Chapman

    • Dear John and Michelle,
      First of all i really need to know the make of the invertor and the Kilowatt rating. Ie Victron Multi Plus 2000va or whatever
      Normally when an inverter says overload it is saying the the demand on it is higher than it can handle.

      This means the battery supply is less than the output potential. What i suggest is a test turn off all your 230v and 12v items used in the boat.

      This must include fridges and tv’s on standby 12v phone chargers etc. Once everything is disconnected see if the invertor is OK.
      Then start to slowly to reconnect your appliances checking the invertor as you go. I suspect there will be a point that the invertor will go overload which will tell
      you what the invertor can take.

      You may need to to do power audit regarding your usage.
      To complete a power audit look up the wattage of each piece of electrical equipment be they DC or AC; then estimate how many hours each will be used in a 24hr period and multiply the wattage by the hours. So if you think a 20W lamp will be used for 3 hours a day on average; this will give 60 Watt hrs. Add all these together and divide this Watt hr total by the boat battery voltage (either 12 or 24V), so using the 20W lamp for 3 hours will use 5Ahrs of battery capacity. If some of the equipment is 230V be sure to add in the quiescent operating power used by the inverter.

      If you are using lead acid batteries, doubling the Ahr figure will give the battery capacity required allowing for 50% discharge. The ideal is four 110ah batteries giving 440 amp hour so your audit should come in at 220amp hour

      Do you know how old the batteries are and what type make and rating??
      If they are getting old then the 12v supply which i presume you have maybe down and not suppling enough voltage/amps.

      Also is your battery charger doing its job? Some boats have a combined charger in the invertor others are separate. Is it charging the batteries fully? Do you know the 12v output reading? Normally it will be above 12v, something like 13v. If it is below 11v than your batteries may well be the problem, causing the overload on the invertor. Try turning on your engine for a while to give them some charge and after a while of charging see what the invertor is saying while engine is still running.

      The Kabola central heating
      Most diesel central heating systems are normally run from your 12v supply. I need to know the model number. They work as diesel water heater. The system may use a 12v supply to ignite the burner and run the water pump.

      Please DO NOT hot wire the Kabola until you know what its supply is. I do know that the Kabola Compact 7 is run by 230AC and not DC but i believe there were marine version that were not.
      If you establish it is 230c AC go here for spec info https://kabolaheaters.nl/en/products/
      The thing with hot wiring from the shore line is you will need to fuse and earth protect the system so you are electrically safe. After that you will have no problem running the system to get you by.
      Please note when you hot wire your boat, it is not protected by your galvanic isolator if fitted.

      Hope this helps.

      If you want more on batteries then go here https://www.canalnarrowboat.co.uk/living-aboard/batteries/

  4. Nice site. Nice to see its mobile friendly. I found this helpful as i use my phone a lot on the internet. I found some great information here. I will be visiting again.

Leave a Reply

Your email address will not be published. Required fields are marked *